Easy to use1 to 3 day turnaround calibrationexcellent for UV Curing applications

Model 320 Data Sheet


Model 320

The Model 320

The Model 320 is a simplification of the Model 400. As in the 400, a built-in computer allows storing of sensor readings and calculations of average value and percent deviations. The two line display format allows for several readings at one time. The Model 320 measures MW/CM2, peak MW/CM2, MJ/CM2 (single pulse), accumulated MJ/CM2, time (single pulse), and accumulated seconds.

The Model 320 has four modes of operation. Mode 3 (MW/CM2) and Mode 4 (MJ/CM2) allow taking five readings in a fixed pattern and then displaying the average value and the +/-% uniformity as well as the +/-% deviation from the center value.

The rechargeable battery lasts for about 18 hours and the charger operates from 100-240 VAC, 50-60 Hz with UL, CE, and TUV approvals.

A variety of sensor packages can be used with the Model 320 at wavelengths from 220nm to 540nm and beyond. Traceability to NIST is +/-3.0% with probe matching to +/-1.0%. The Model 320 can be set up to work with a dual channel probe.

Model 320 features
  • Less than 1% Probe to Probe Repeatability.

  • Real Time Measurements.

  • Interchangeable Probes

  • Dual channel probe capability

  • Cosine response probes

  • Measures MW/CM2, peak MW/CM2, MJ/CM2 (SP), accumulated MJ/CM2 time (seconds), and accumulated time

  • Calculates average value, % uniformity and % deviation from center value

  • Battery operates for approximately 18 hours before recharge

  • Charger operates from 100-240 VAC, 50-60 Hz with UL, CE, and TUV approvals



Sensor Spectral Ranges
This graph accurately represents the spectral response of probes used today in the Microelectronic Industry. This graph includes the spectral response of the detector as well as the spectral response of the filter glass used in probes.

Model 320 Specifications

Switch Functions:
  • Red button - ON (hold for one second)
    Off when displayed and MORE (data review)
  • Two black buttons for Mode, Reset
    SEL (select), Back (data review)
  • Channel A, Channel B switch (optional)
Display:
  • 2 Lines by 16 characters
Range:
  • MW/CM2 - .1 to 999.9 (peak same)
  • MJ/CM2 - .1 to 9999.9
  • Time - .001 to 99.999 seconds

Mode Selection:

   Mode 1:   
 
  • MW/CM2 and peak MW/CM2 continuous display
   Mode 2:   
  • MJ/CM2 (single pulse) and accumulated MJ/CM2
  • Time (seconds) and accumulated time.
  • Single pulse - MJ/CM2 and time update automatically with new signal
   Mode 3:   
  • Five readings of mw/CM2 in a *fixed pattern using a one second shutter opening (minimum) to read mw/CM2
  • Display of average mw/CM2 and +/-% uniformity
  • Display of +/-% deviation of each reading from center value
  • Display of all five values (3 digits)
   Mode 4:   
  • Five readings of MJ/CM2 in a *fixed pattern ~ shutter control
  • Display of average MJ/CM2 and +/-% uniformity
  • Display of +/-% deviation from center reading
Display Pattern:

2
5
1
3
4
Power:
  • Built in rechargeable battery - 18 hours operation (approx.)
  • Recharge time 6 hours (unit off) - indicated by LED (goes dim and then off when fully charged)
  • Low battery indication on display next to 'OFF'
  • Charger - 100-240 VAC, 50-60 Hz
  • Charger is UL, CE, TUV approved
Probe Wavelengths:
  • 220nm, 248nm, 254nm, 260nm, 280nm, 310nm, 365nm, 400nm, 420nm, 436nm, 540nm, and more
Size:
  • 5.5 in. W (14 cm) x 7.4 in. L (18.8 cm) x 1.5 in. H (3.8 cm)
Weight:
  • 1.5 lbs. (681 grams)