Meter Comparisons

Print Version

Meter/Scales Operation Probes
Model 100

0.01 to 199.99 MW/CM2

or 0.1 to 1999.9 MW/CM2

On/Off switch Single Probe

Any Wavelength

Model 200

0.01 to 199.99 MW/CM2

and 0.001 to 19.999 W/CM2

On/Off Switch

Range Switch

Peak Hold Switch

Single Probe

Any Wavelength

Model 202

0.01 to 199.99 MW/CM2

and 0.001 to 19.999 W/CM2

On/Off switch

Range Switch

Channel A/Channel B Switch

Hold/On Switch

Single or Dual Probe

Any Wavelength

Model 320

0.1 to 999.9 MW/CM2

Peak Same

0.1 to 9999.9 MJ/CM2

0.001 to 99.999 Seconds

4 Modes Of Operation

  1. MW/CM2 and Peak MW/CM2
  2. MJ/CM2 (single pulse) and accum. MJ/CM2
    • Time (sec.) & accum. time
    • Single pulse MJ/CM2 and time up date automatically with new signal
  3. Five readings of MW/CM2 in a fixed pattern using a one second shutter opening (min.)
    • Display of average MW/CM2 and +/-% uniformity
    • Display of +/-% deviation of each reading from the center value
    • Display of all five values (3 digits)
  4. Five readings of MJ/CM2 in a fixed pattern~shutter control
    • Display of average MJ/CM2 and +/-% uniformity
    • Display of +/-% deviation from center value
Single Probe

Any Wavelength

(Dual Probe Option)

Nikon

Ultratek

Model 400

MW/CM2 0.1 to 2300.0

MJ/CM2 0.1 to 9999.9

Milliseconds 0.1 to 9999.9

Nikon Modes – Nikon Probe

  1. MW/CM2 and peak MW/CM2 continuous display
  2. Multiple readings of MJ/CM2 and time to determine consistency of a system exposure using shutter control
    • Display of average MJ/CM2 and +/-% uniformity
    • Display of ten readings of MJ/CM2
  3. Reading of MJ/CM2 in four sets. Any number of shutter openings from 2 to
    10 per set, Target values of 400 MJ/CM2 (set1), 200 MJ/CM2 (set2), 100 MJ/CM2
    (set3) and 50 MJ/CM2 (set4). Records all shutter opening values and displays
    for each set, The average value, standard deviation 3 sigma, range (max-min),
    values of MJ/CM2 and the % deviation from the target value of each reading.
  4. Reads MW/CM2 and peak MW/CM2for nine shutter openings of one second
    (minimum). Displays the average MW/CM2, the +/-% deviation from the average
    value, all nine readings and the maximum and minimum readings.

Area Exposure Modes – Regular Probes all Wavelengths (Ultratek)

  1. MW/CM2 and peak MW/CM2 continuous display
  2. Multiple readings of MW/CM2 for uniformity measurement
    • Push button STO (store) of reading-nine readings in set pattern
    • Display of average MW/CM2 and +/-% uniformity
    • Display of + or – % deviation from center reading
  3. Single reading and accumulated MJ/CM2, time and peak MW/CM2
    • Shutter control or scanning beam (Perkin Elmer)
  4. Multiple readings of MJ/CM2, time and peak MW/CM2
    • Shutter control of readings-nine readings in set pattern
    • Display of average MJ/CM2 and +/-% uniformity
    • Display of + or – % deviation from center reading
  5. Multiple readings of MW/CM2 and peak MW/CM2 using shutter control of the measurement (one second) to measure source uniformity-line pattern-(circular pattern available)
    • Display of average intensity MW/CM2 and the +/-% uniformity
    • Display of + or – % deviation from center reading
    • Display of all nine readings
    • Display of max and min reading