| Meter/Scales |
Operation |
Probes |
| Model 100
0.01 to 199.99 MW/CM2
or 0.1 to 1999.9 MW/CM2 |
On/Off switch |
Single Probe
Any Wavelength |
| Model 200
0.01 to 199.99 MW/CM2
and 0.001 to 19.999 W/CM2 |
On/Off Switch
Range Switch
Peak Hold Switch |
Single Probe
Any Wavelength |
| Model 202
0.01 to 199.99 MW/CM2
and 0.001 to 19.999 W/CM2 |
On/Off switch
Range Switch
Channel A/Channel B Switch
Hold/On Switch |
Single or Dual Probe
Any Wavelength |
| Model 320
0.1 to 999.9 MW/CM2
Peak Same
0.1 to 9999.9 MJ/CM2
0.001 to 99.999 Seconds |
4 Modes Of Operation
- MW/CM2 and Peak MW/CM2
- MJ/CM2 (single pulse) and accum. MJ/CM2
- Time (sec.) & accum. time
- Single pulse MJ/CM2 and time up date automatically with new signal
- Five readings of MW/CM2 in a fixed pattern using a one second shutter opening (min.)
- Display of average MW/CM2 and +/-% uniformity
- Display of +/-% deviation of each reading from the center value
- Display of all five values (3 digits)
- Five readings of MJ/CM2 in a fixed pattern~shutter control
- Display of average MJ/CM2 and +/-% uniformity
- Display of +/-% deviation from center value
|
Single Probe
Any Wavelength
(Dual Probe Option)
Nikon
Ultratek |
| Model 400
MW/CM2 0.1 to 2300.0
MJ/CM2 0.1 to 9999.9
Milliseconds 0.1 to 9999.9 |
Nikon Modes – Nikon Probe
- MW/CM2 and peak MW/CM2 continuous display
- Multiple readings of MJ/CM2 and time to determine consistency of a system exposure using shutter control
- Display of average MJ/CM2 and +/-% uniformity
- Display of ten readings of MJ/CM2
- Reading of MJ/CM2 in four sets. Any number of shutter openings from 2 to
10 per set, Target values of 400 MJ/CM2 (set1), 200 MJ/CM2 (set2), 100 MJ/CM2
(set3) and 50 MJ/CM2 (set4). Records all shutter opening values and displays
for each set, The average value, standard deviation 3 sigma, range (max-min),
values of MJ/CM2 and the % deviation from the target value of each reading.
- Reads MW/CM2 and peak MW/CM2for nine shutter openings of one second
(minimum). Displays the average MW/CM2, the +/-% deviation from the average
value, all nine readings and the maximum and minimum readings.
Area Exposure Modes – Regular Probes all Wavelengths (Ultratek)
- MW/CM2 and peak MW/CM2 continuous display
- Multiple readings of MW/CM2 for uniformity measurement
- Push button STO (store) of reading-nine readings in set pattern
- Display of average MW/CM2 and +/-% uniformity
- Display of + or – % deviation from center reading
- Single reading and accumulated MJ/CM2, time and peak MW/CM2
- Shutter control or scanning beam (Perkin Elmer)
- Multiple readings of MJ/CM2, time and peak MW/CM2
- Shutter control of readings-nine readings in set pattern
- Display of average MJ/CM2 and +/-% uniformity
- Display of + or – % deviation from center reading
- Multiple readings of MW/CM2 and peak MW/CM2 using shutter control of the measurement (one second) to measure source uniformity-line pattern-(circular pattern available)
- Display of average intensity MW/CM2 and the +/-% uniformity
- Display of + or – % deviation from center reading
- Display of all nine readings
- Display of max and min reading
|